Quantum Sniffer QS-H150 portable explosives detector

  • Photonic (non-radioactive) ionization
  • Patented vortex collector
  • Automated continuous calibration
  • No materials for verification & calibration needed
  • Simultaneous detection of vapours and solid particles

AvailableInStock

  • Print

More info

Quantum Sniffer QS-H150 portable explosives detector

Quantum Sniffer QS-H150 detector takes use of a patented vortex collector, which enables a simultaneous detection of both particles and vapours in the real time, in a physical contact with a substance or without it.

  • Alarm

    Alarm

    sound

    visual

  • Automatic calibration

    Calibration

    automated

  • LCD

    Display

    built-in LCD

  • Operation time

    Operation time

    up to 4 hours

QS-H150 portable explosives detector is also featured with a continuous automated calibration. The device keeps monitoring the surroundings and register the changes which may take effect on the precision of measurement. While the device operates in a measurement mode it also makes automatically the appropriate corrections in calibration at the same time. A user is in no way engaged in this process, no other materials or pauses in operation are needed either.

During a detecting process the samples are taken by means of an air vortex. In the next step they undergo the photonic ionization and finally they are analyzed via ion mobility spectrometry technique. The presence of dangerous substances is signaled with a sound and visual alarm. Also the type of detected substances is displayed on the built-in LCD display. There's an option to connect to a keyboard and a screen to the device, what allows a user a convenient access to the spectrogram view and interface of analytic, diagnostic and administrational tools.

The detection of dangerous substances by the device is signaled immediately. The real-time detection technology highly reduces the possibilities of contamination a device and allows for a quick restoration of operability.

The cost of the consumables used by the detector has been reduced to the bare minimum, what makes the maintenance and operation processes be very money-saving. In fact, during everyday routine operation the device needs only maintenance and cleaning with the most popular and affordable cleaners, and exchange of a desiccant if need arises.

Quantum Sniffer QS-H150 is a device far more sensitive then the similar detectors. It can detect the vapours of the explosives at the threshold of single molecules, i.e. at the parts-per-billion or in case of solid mass at the micro quantity level of nanograms.

­

No licensing!
QS -150 detector doesn't use any radioactive substances and thus needs no certifications, licenses, authorized overhauls or special and embarrassing utilization procedures.

Main advantages

  • Low cost of operation
  • Very low rate of false detections
  • Full spectrum of detectable substances
  • Expandable library of dangerous substances
  • Quick analysis
  • Superfast clear down and ready to work
  • Reduced maintenance requirements

Product video

Specification of drug and explosives detector QS-H150
1 The list does not include all of the substances detected by QS-B220. The substances in the library may vary depending on the system settings and configuration. New substances can be added throug extended library.
Type of sensorSpectrometer of ion mobility (IMS) using a phenomena of non-radioactive photonic ionization
Sampling frequency
  • not less than 180 samples per hour unless no detections
  • automatically restored to a standby mode - no action from a user needed
  • operation capability restored usually in less than 10 s
Display
  • 12.5" (38 cm)
  • color high resolution touchscreen
Time of warm-up and ready to operationmax 30 min
Samplingsolid particles are taken with a wipe
Calibrationautomated inner calibration system inCal
Signaling
  • User-adjustable sound and visual alarm
  • Identification of a substance with its name (dependant on a configuration)
Connectors4 USB 2.0 sockets for peripherals (printers, mouse, keyboard). RJ45 Ethernet socket allows for monitoring, remote control and diagnostics of the unit. A VGA socket.
Detectable substances 1
  • Explosives: of military usage, civil usage and ad-hoc prepared, including ammonium nitrate, ammonium nitrate fuel oil (ANFO), C-4, Detasheet, detonating cords, Dinitrotoluene, DMNB, dynamite, EGDN, HMTD, HMX, nitroglycerine, peroxides, smokeless and black powder, PETN, RDX, semtex, tetryl, TATP, TNT, urea nitrate and others.
  • Cocaine, heroin, ketamine, L-amphetamine, LSD, MDS, MDMA, methamphetamine, morphine, PCP, spice, THC and others
Power supply
  • input voltage: 100-240 VAC, 47-63 Hz
  • Power consumption peak 350 W (standard 225 W)
Operation conditions
  • admissible temperature: -15 up to 55°C
  • admissible height: 4572 mnpm
  • admissible humidity: 0 up to 95% no evaporation
Dimensions
  • 42,5×36,9×40,4 cm (none printer)
  • 42,5×39,9×40,4 cm (with printer)
Weight14.6 kg (without a printer) or 15.7 kg (with a printer)
Additional consumables
  • verification sample Negative, Desicant/ Molecular Seive cansiter, Dessicant/Molecular Sieve Absorbant
  • Calibrant Cartridge
  • Durable sample traps for wipe sampling (100 per can)
Inbox
  • Quantum Sniffer QS-H150 portable explosives detector
  • User manual
­

Additional consumables:
Verification of negative samples
Dessicant / molecular sieve canister
Dessicant / molecular sieve absorbant
Calibrant cartridge
Durable sample for wipe sampling (100 per can)
Price for one set: 1199 GBP

Manufacturer

Implant Sciences

Implant Sciences is a world leader in design and production of devices, which aims and objectives are to detect any type of dangerous chemical compounds like explosives and drugs of abuse. The company considerably stands out on a background of their competitors by using the...

Specification

Specification of drug and explosives detector QS-H150
1 The list does not include all of the substances detected by QS-B220. The substances in the library may vary depending on the system settings and configuration. New substances can be added throug extended library.
Type of sensorSpectrometer of ion mobility (IMS) using a phenomena of non-radioactive photonic ionization
Sampling frequency
  • not less than 180 samples per hour unless no detections
  • automatically restored to a standby mode - no action from a user needed
  • operation capability restored usually in less than 10 s
Display
  • 12.5" (38 cm)
  • color high resolution touchscreen
Time of warm-up and ready to operationmax 30 min
Samplingsolid particles are taken with a wipe
Calibrationautomated inner calibration system inCal
Signaling
  • User-adjustable sound and visual alarm
  • Identification of a substance with its name (dependant on a configuration)
Connectors4 USB 2.0 sockets for peripherals (printers, mouse, keyboard). RJ45 Ethernet socket allows for monitoring, remote control and diagnostics of the unit. A VGA socket.
Detectable substances 1
  • Explosives: of military usage, civil usage and ad-hoc prepared, including ammonium nitrate, ammonium nitrate fuel oil (ANFO), C-4, Detasheet, detonating cords, Dinitrotoluene, DMNB, dynamite, EGDN, HMTD, HMX, nitroglycerine, peroxides, smokeless and black powder, PETN, RDX, semtex, tetryl, TATP, TNT, urea nitrate and others.
  • Cocaine, heroin, ketamine, L-amphetamine, LSD, MDS, MDMA, methamphetamine, morphine, PCP, spice, THC and others
Power supply
  • input voltage: 100-240 VAC, 47-63 Hz
  • Power consumption peak 350 W (standard 225 W)
Operation conditions
  • admissible temperature: -15 up to 55°C
  • admissible height: 4572 mnpm
  • admissible humidity: 0 up to 95% no evaporation
Dimensions
  • 42,5×36,9×40,4 cm (none printer)
  • 42,5×39,9×40,4 cm (with printer)
Weight14.6 kg (without a printer) or 15.7 kg (with a printer)
Additional consumables
  • verification sample Negative, Desicant/ Molecular Seive cansiter, Dessicant/Molecular Sieve Absorbant
  • Calibrant Cartridge
  • Durable sample traps for wipe sampling (100 per can)

Inbox

  • Quantum Sniffer QS-H150 portable explosives detector
  • User manual
­

Additional consumables:
Verification of negative samples
Dessicant / molecular sieve canister
Dessicant / molecular sieve absorbant
Calibrant cartridge
Durable sample for wipe sampling (100 per can)
Price for one set: 1199 GBP