- Average: 0
Nobody has posted a review yet
Rate / write a comment Sales representative and Consultant
John Paine
Helpdesk
+44 (020) 3290 1199
Nobody has posted a review yet | |
Rate / write a comment |
Helpdesk
+44 (020) 3290 1199
Product unavailable!
Order a similar product: Gas leak detector Drager PAC 6500 for portable detection of O2, H2S, CO, SO2 .
Drager 5500 - CO is a hand-held gas detector which enables quick and easy detection of carbon monoxide leakage e.g. at the work station, in sewage manholes, sewage treatment plants and etc. Ergonomic design, simple operation, clear alarm system and high resistance ensure efficient work and satisfaction.
2 buttons
DrägerSensor XXS
9 V battery
IrDA
Pocket-size Drager Carbon monoxide detector enables quick location of CO leakage. The device has been equipped with a sensitive sensor and a filter that can be quickly and easily replaced. The double air-inlet system in the front panel and at the top increases the functionality of the device.
The Drager CO Carbon monoxide detector allows you to quickly diagnose carbon monoxide leakage in a room. The device is robust, easy to use and sensitive. You can easily change the 3V battery when it suddenly gets discharged. The device has been designed for monitoring air pollution with carbon monoxide in flats, sewage treatment plants or during rescue operation.
Gas gauges
In Detective Store offer you will also find detecting volatilization of flammable hydrogen sulphide Drager 5500 H2Sand Drager O2 detecting volatilization of oxygen.
Drager XXS sensor provides sensitivity of the Carbon monoxide detector and guarantees the quickest measurement when compared to competing devices. The use of two air inlets at the top and in the front prevents interruption of work in the event when one of the inlets is covered.
For the detector to work properly for a long time, calibration is required. It is possible to carry out short tests to check the correct operation of the gauge. The test time does not exceed 15 s.
The Carbon monoxide detector can be used in potentially explosive areas Z1 and Z2 (gas, smoke, fog) explosion groups classified as IIA, IIB, IIC and in areas with temperature classes T1, T2, T3 and T4..
Intuitive alarm system informs about errors through sound, vibration and backlight.
The liquid crystal screen is readable both on a sunny day and after highlighting in the dark.
The gas detector has a built-in memory that stores up to 60 indications. Thanks to the IrDA interface, it is possible to download alarms for further analysis of their occurrence.
5500 CO | 5500 H2S | 5500 O2 | |
---|---|---|---|
Range | 0 – 500 ppm | 0 – 100 ppm | 0 – 100 ppm |
Alarm thresholds | 30/ 60 ppm | 10/ 20 ppm | 19/ 23% vol |
Resolution | 2 ppm | 0,1 ppm | 0.1% vol |
Response time | 15 s | 15 s | 10 s |
Specification of the carbon monoxide detector Drager 5500 - CO | |
---|---|
Number of detected gases | 1 |
Type of detected gases | CO |
Measuring range | 0 - 500 ppm |
Sound alarm | 95 dB/ 0,3 m |
Vibration alarm | yes |
Light indication | yes |
Admissible humidity | 10 - 90% |
Protection class | IP65 |
Device oeration standards | EExia and II CT4 |
Operation temperatre of the carbon monoxide detector | -30°C - +50°C |
Dimensions | 84×64×25 mm |
Weight | 120 g |
Inbox |
---|
Specification of the carbon monoxide detector Drager 5500 - CO | |
---|---|
Number of detected gases | 1 |
Type of detected gases | CO |
Measuring range | 0 - 500 ppm |
Sound alarm | 95 dB/ 0,3 m |
Vibration alarm | yes |
Light indication | yes |
Admissible humidity | 10 - 90% |
Protection class | IP65 |
Device oeration standards | EExia and II CT4 |
Operation temperatre of the carbon monoxide detector | -30°C - +50°C |
Dimensions | 84×64×25 mm |
Weight | 120 g |